Interface-Cable for S7 V1.6

MPI/PPI-Kabel 9350 for Simatic S7-200 up to S7-400
Please connect the cable to the serial port (Com-Port) of your pc and to the MPI- or PPI-Port of your plc. After, the cable has be started, you can see in the display of the cable how much devices and their address are connected to the bus. In your S7- programming software you should configure following:
 

Siemens S7-300/400: [STEP7]
Under options > Set PG/PC Interface… please select the driver “PC-Adapter MPI]” and configure it like the properties of the mpi-bus. If your software don’t have this driver, you should have to install it now. You don’t need the software CD, the driver is included in your Siemens software. You should press the button “Add/remove” in this menu. You can also install the driver called “MPI-Speed” (see link to the homepage) to your system. This driver allows to communicate serial up to 115K2 Baud. The original driver “PC-Adapter [MPI]” only provides baudrates up to 38K4 baud.

Siemens S7-200: [MicroWin]
Under Set PG/PC Interface… please select the driver PC/PPI-cable. The configured PPI-baudrate of 9K6 or 19K2 will be recognised of the connected
MPI/PPI-Kabel. Please note, that the cable will make this only after starting up. If you have a change of the baudrate, please restart the cable!
This cable is not able to drive with a MultiMaster – network.

PG-95/2000:
Under option > interface you select the com-port and the baudrate up to 115K2 Baud.
 
S7 for Windows:
Under file > properties > interface select the protocol for “MPI Converter (Simatic S7)” and configure the correct com-port and the baudrate up to
115K2.

MPI-II-Kabel 9352 for Simatic S7-200 up to S7-400
Please connect the cable to the serial port (Com-Port) of your pc and to the MPI- or PPI-Port of your plc. After, the cable has be started, you can see in the display of the cable how much devices and their address are connected to the bus. In your S7- programming software you should configure following:
 

 

Siemens S7-300/400: [STEP7]

Under options  > Set PG/PC Interface… please select the driver “PC-Adapter MPI]” and configure it like the properties of the mpi-bus. If your software
don’t have this driver, you should have to install it now. You don’t need the software CD, the driver is included in your Siemens software. You should press the button “Add/remove” in this menu.
For the connection to the profibus, please use the driver “PC-Adapter Profibus]”.
 
For details, please download here
 

 


Related articles:

Powered By relatedArticle

Blog Catalog

My BlogCatalog BlogRank

Blog Directory

Blog Directory & Search engine

Blog Directory

Technology

Visitors Counter

mod_vvisit_countermod_vvisit_countermod_vvisit_countermod_vvisit_countermod_vvisit_countermod_vvisit_counter
mod_vvisit_counterToday93
mod_vvisit_counterYesterday165
mod_vvisit_counterThis week624
mod_vvisit_counterLast week811
mod_vvisit_counterThis month1114
mod_vvisit_counterLast month3010
mod_vvisit_counterAll days22845